1
Hi, Guest!

  LOKASI :  Jakarta

  AKTIVITAS :  13/08/2019

BAGIKAN :   

Bagikan :
Masukan Data Diri Anda
Nama harus diisi !
Email harus diisi !
Format email harus someone@example.com !
DISTRIBUTOR ELECTRIC MOTOR , GEAR MOTOR , GEAR REDUCER , GEARBOX , PUMP, COUPLING, PULLEY, CHAIN, CONVEYOR CHAIN, SPROCKET

DELTA INVERTER SERI VFD PT SARANA TEKNIK DELTA INVERTER

Update Terakhir
:
27 / 05 / 2019
Min. Pembelian
:
1 Unit
Harga
CALL
Bagikan
:
Selamat datang di website www.sarana-teknik.co.idPT. Sarana Teknik berdiri sejak Oktober 1998 adalah Perusahaan yang menjadi distributor transmisi tenaga mekanik & produk motor listrik. Dengan penghargaan dari custumer akhir nya kami menjadi di kenal dengan Stokist pada product sebagai berikut : BALDOR MOTOR DODGE COUPLING - DODGE BEARING FALK COUPLING REXNORD COUPLING - REXNORD CHAIN ADDAX COUPLING , THOMAS, FENNER BELT COUPLING PULLEY , SIHI PUMP, KOSHIN GEAR PUMP, SOUTHERN CROSS PUMP, EBARA PUMP, FRANKLIN SUBMERSIBLE PUMP, KENFLO PUMP, BEARING, BANDO BELT, CONTINENTAL CONVEYOR BELT MARTIN, LINK BELT, HITACHI, MTK, NIKKEN, KHK, KTR, KB PENTA POWER, CUTES INVERTER, TOSHIBA INVERTER, DELTA INVERTER, KBMM, TECO MOTOR, SIEMENS MOTOR, YUEMA ELECTRIC MOTOR, TSUBAKI POWER HELICAL DRIVE REDUCER, KOP-FLEX, TB WOOD' S, FLENDER, NBK, KTR, MITSUBOSHI, CENTA, EBARA, MOTOVARIO , MOTOVARIO GEARBOX , MOTOVARIO INDONESIA , MOTOVARIO WORM GEAR , BONFIGLIOLI , BONFIGLIOLI INDONESIA , BONFIGLIOLI RIDUTTORI , BONFIGLIOLI GEARMOTOR, dllUntuk informasi dan pemesanan Hubungi Kami :Head Office PT. Sarana TeknikKompleks Perkantoran Sunter Permai Blok B.11, Jl. Danau Sunter Utara Kav. K-2, Sunter Agung Jakarta 14350 IndonesiaPhone : ( 021) 651-9582 ( Hunting)Fax : ( 021) 65305868 – 6400893Fax Bebas Pulsa : 0800-1-666-777Email : sarana@bit.net.id // saranateknik@cbn.net.idWebsite : www.sarana-teknik.comBranch OfficeA. CikarangSimprug Plaza Blok A2 No.11, JABABEKA 2 Cikarang - BekasiPhone : ( 021) 8932 4575, 8932 4587Fax   : ( 021) 8932 4530Email : sarana_ cikarang@ cbn.net.id // saranagroup@cbn.net.idAttn. BAPAK FARID ILHAMSYAHB. SurabayaRuko Sentra Tropodo Blok C-7 Jl. Raya Tropodo No. 115, Waru – SurabayaPhone : ( 031) 8685823–24Fax   : ( 031) 8685825Email : sarana_ surabaya@cbn.net.id/ saranagroup@cbn.net.idAttn. BAPAK JUANDI/ NANANG

Detail DELTA INVERTER SERI VFD PT SARANA TEKNIK DELTA INVERTER

PT SARANA TEKNIK DELTA INVERTER
EMAIL : SARANAGROUP@CBN.NET.ID

DELTA’s high-perform
ance VFD-B Series. The VFD-B Series is manufactured with high-quality components and materials and incorporates the latest microprocessor technology available. Getting Started This quick start will be helpful in the installation and parameter setting of the AC motor drives. To guarantee safe operation of the equipment, read the following safety guidelines before connecting power to the AC motor drives. For detail information, refer to the VFD-B User Manual on the CD supplied with the drive. DANGER!1. AC input power must be disconnected before any wiring to the AC motor drive is made. 2. A charge may still remain in the DC-link capacitors with hazardous voltages, even if the power has been turned off. To prevent personal injury, please ensure that power has turned off before opening the AC motor drive and wait ten minutes for the capacitors to discharge to safe voltage levels. 3. Never reassemble internal components or wiring. 4. The AC motor drive may be destroyed beyond repair if incorrect cables are connected to the input/output terminals. Never connect the AC motor drive output terminals U/T1, V/T2, and W/T3 directly to the AC mains circuit power supply. 5. Ground the VFD-B using the ground terminal. The grounding method must comply with the laws of the country where the AC motor drive is to be installed. Refer to the Basic Wiring Diagram. 6. VFD-B series is used only to control variable speed of 3-phase induction motors, NOT for 1-phase motors or other purpose. 7. VFD-B series shall NOT be used for life support equipment or any life safety situation. WARNING!1. DO NOT use Hi-pot test for internal components. The semi-conductor used in AC motor
AC INVERTER AC
Tampilkan Lebih Banyak
pt. sarana teknik
pt. sarana teknik

PT. SARANA TEKNIK

PREMIUM GOLD 9 Tahun
Komplek Perkantoran Sunter Permai Blok B11 Jl. Danau Sunter Utara Kav. K-2 Sunter Agung TEL 6519682
EMAIL : SARANAGROUP@CBN.NET.ID, Jakarta
Indonesia 14350
Jakarta
13 / 08 / 2019
Hubungi Kami

Detail DELTA INVERTER SERI VFD PT SARANA TEKNIK DELTA INVERTER

PT SARANA TEKNIK DELTA INVERTER
EMAIL : SARANAGROUP@CBN.NET.ID

DELTA’s high-perform
ance VFD-B Series. The VFD-B Series is manufactured with high-quality components and materials and incorporates the latest microprocessor technology available. Getting Started This quick start will be helpful in the installation and parameter setting of the AC motor drives. To guarantee safe operation of the equipment, read the following safety guidelines before connecting power to the AC motor drives. For detail information, refer to the VFD-B User Manual on the CD supplied with the drive. DANGER!1. AC input power must be disconnected before any wiring to the AC motor drive is made. 2. A charge may still remain in the DC-link capacitors with hazardous voltages, even if the power has been turned off. To prevent personal injury, please ensure that power has turned off before opening the AC motor drive and wait ten minutes for the capacitors to discharge to safe voltage levels. 3. Never reassemble internal components or wiring. 4. The AC motor drive may be destroyed beyond repair if incorrect cables are connected to the input/output terminals. Never connect the AC motor drive output terminals U/T1, V/T2, and W/T3 directly to the AC mains circuit power supply. 5. Ground the VFD-B using the ground terminal. The grounding method must comply with the laws of the country where the AC motor drive is to be installed. Refer to the Basic Wiring Diagram. 6. VFD-B series is used only to control variable speed of 3-phase induction motors, NOT for 1-phase motors or other purpose. 7. VFD-B series shall NOT be used for life support equipment or any life safety situation. WARNING!1. DO NOT use Hi-pot test for internal components. The semi-conductor used in AC motor
AC INVERTER AC
Tampilkan Lebih Banyak